1212..44 Upgrading the SoftwareUpgrading the Software
Connect the AC adapter to the Network Master while updating the software.
When updating the software with battery operation, make sure that there is 40% (or
more) power in the battery of the Network Master.
1212..44..11 Installation by using USB memory stickInstallation by using USB memory stick
Visit our website and download the latest version. We have two types of
installers as below.
MT1000A_Software with MU100011A: For using MT1000A which module
configuration includes MU100011A.
MT1000A_Software: For using MT1000A which module
configuration does not include MU100011A.
"MT1000A_Software with MU100011A" is consisted from two files. Copy both files to
USB memory stick and perform the installation.
Note that installing "MT1000A_Software" is not able to work the MU100011A.
1. Copy the installer onto an empty USB memory stick.
2. If USB memory stick is inserted to the Network Master, remove it. If the
Network Master is powered-down while the USB memory stick is still inserted,
there is a risk that the USB memory stick may not operate normally after the
installation.
3. Press the power button to shut down the Network Master. Never force to power
off by holding the power button pressed for several seconds.
4. Remove AC adapter or power cable and confirm the power button turns to
gray.
5. Insert the USB memory stick into the Network Master.
6. Connect AC adapter to the Network Master.
7. Press the power button to boot the Network Master.
The Network Master will detect the installer stored in the USB memory stick,
and start installing the software. After the installation has finished, the
Network Master will reboot.
If the software is installed on battery operation without connecting AC adapter,
Network Master does not reboot. Press the power button to boot the Network
Master.
When installing MT1000A software which includes MU100011A, the
installation of MU100011A data starts automatically at the Network Master
rebooting.
8. Check the software version at System Information on the Instrument ToolbarInstrument Toolbar.
9. Remove USB memory stick after the installation has completed.
1212..44..22 Installation via NetworkInstallation via Network
1. Install MX100001A MT1000A/MT1100A Control Software to PC by referring
to 3.5.1 Installation of Control Software.
2. Configure the Control Software and the Network Master so that they can
communicate via Ethernet by referring to 3.5.2 Connection and Setup.
3. Upgrade the software by referring to 3.5.5 Remote Upgrade.