DurationDuration
Frames per Burst Frames per Burst
(Burst Length)(Burst Length)
StepStep
Specify an approximate duration for each step of the test by time.
99..33..22..55 BurstBurst
The following screen is displayed by touching BurstBurst in the Navigation area.
Auto SearchAuto Search
When the check box is selected, the burst length is automatically searched.
Select Search Mode. The resolution is selected from 11, 1010, or 100100.
The range of searching the burst size is set at Start burst sizeStart burst size and End burstEnd burst
sizesize.
SteppedStepped
The burst size is changed in steps. The range of changing the burst size is set at
Start burst sizeStart burst size and Stop burst sizeStop burst size. And the change amount per step is set at
Step burst sizeStep burst size.
When the burst size is set as follows, it is changed from 100 to 900 (100 -> 300 -> 500 -
> 700 -> 900).
Start burst size: 100
End burst size: 1000
Step burst size: 200
99..33..22..66 CreditCredit
The following screen is displayed by touching CreditCredit in the Navigation area.
PerformancePerformance
491491