400HD Series IP Phones
Administrator's Manual 290 Document #: LTRT-11950
Parameter Description
Redundant Proxy Mode
[voip/signalling/sip/redundant_proxy/mode]
The call center's network administrator can
select either
Disable -OR-
Primary Fallback -OR-
Simultaneous
For the dual-registration feature, select
Simultaneous; two proxies are registered
simultaneously so that at least one should be
up and running at any time, preventing the call
center from going down.
Note that when using the BroadSoft ACD in a
SIP Business Continuity deployment, this
parameter cannot be set to Simultaneous.
Secondary Proxy Address
[voip/signalling/sip/secondary_proxy/address]
Displayed only when Simultaneous is
selected for 'Redundant Proxy Mode' (see
previous parameter). Define the IP address of
the secondary proxy that will be up
simultaneously with the primary.
Secondary Proxy Port
[voip/signalling/sip/secondary_proxy/port]
Displayed only when Simultaneous is
selected for 'Redundant Proxy Mode' (see the
parameter before the previous). Define the
port of the secondary proxy that will be up
simultaneously with the primary.