MP-202 Telephone Adapter 108 Document #: LTRT-50605
User's Manual
¾ To configure separate VLANs for VoIP, Data and Management
packets:
1. (For MP202-1) Open menu Advanced > Remote Administration; open 'Using Primary
HTTP Port (80)' and 'Allow Incoming ICMP Echo Requests (e.g. pings and ICMP
traceroute queries)'
2. For VOIP, add VLAN ID 300. Set the new WAN interface to use static route 3.3.3.3.
Choose advanced route. In ‘advanced route’, choose ROUTE mode, device metric = 0
and check the 'default gateway' check box.
3. For Data, add VLAN ID 521. Set the new WAN interface to use static route 5.5.5.5.
Choose advanced route. In 'advanced route', choose NAPT mode, device metric = 1
and check the 'default gateway' check box.
4. For Management, add VLAN ID 311. Set the new WAN interface to use static route
11.11.11.11. Choose advanced route. In 'advanced route', choose ROUTE mode,
device metric = 2 and check the 'default gateway' check box.
5. Add static route. Do so for all packets with destination IP 11.11.x.x, to use default the
device whose address is 11.11.11.11.
6. To deny access to web management for all interfaces except VLAN 311, add an 'input
rule' in 'advanced filtering' and deny all HTTP packets. Do this for each interface
except the interface with VLAN 311.
7. Repeat the same steps for MP202-2. Use a different IP address.
8. To access the web management for both MP-202-1 and MP-202-2, connect a PC that
works on the same VLAN management (311).
Defining a VLAN, Configuring its Interface
¾ To define an interface VLAN:
1. Open menu Network Connections > New Connection > Advanced Connection > VLAN
Interface; the screen VLAN Interface opens (refer to the figure).
Figure 10-15: Example of Using VLAN - VLAN Interface Screen

Table of Contents

Other manuals for AudioCodes MP-202

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MP-202 and is the answer not in the manual?

AudioCodes MP-202 Specifications

General IconGeneral
ModelMP-202
CategoryAdapter
Ports2 FXS ports
Protocol SupportSIP, H.323
Weight0.5 kg
Operating Temperature0°C to 40°C
Storage Temperature-20°C to 70°C
Humidity10% to 90% non-condensing
Network Interface10/100Base-T Ethernet
Voice CodecsG.711, G.729, G.723.1, G.726
SecurityHTTPS, TLS, SRTP
ManagementWeb-based, SNMP
Power Supply12V DC