MP-202 Telephone Adapter 132 Document #: LTRT-50605
User's Manual
Username
Password
ExternalIPAddress
DNSServers
TransportType
PPPoEACName
PPPoEServiceName
The MP-202 supports the following Remote Procedure Calls (RPCs):
GetRPCMethods
SetParameterValues
GetParameterValues
GetParameterNames
SetParameterAttributes
GetParameterAttributes
AddObject
DeleteObject
Download
Reboot
Note that the implementation of SetParameterAttributes is empty; MP-202 does not
implement access control nor notifications as defined in the specification.
11.2.1 Viewing, Changing TR-069 Parameters Using the CLI
TR-069 parameters can be viewed and configured via the CLI. This section presents a
specific example of how to view and change TR-069 parameters. Use the example as a
guide.
¾ To run CLI commands:
1. Open Telnet
2. Access the system from a PC connected to the LAN port of the MP-202 Telnet
192.168.2.1
3. Enter the administrator user and password.