Page #133 background image
Version 2.6 133 May 1
MP-202 Telephone Adapter 11. TR-069 CPE WAN Management Protocol
¾ To view the current TR-069 settings, run these commands:
rg_conf_print manufacturer/vendor_name
rg_conf_print manufacturer/vendor_oui
rg_conf_print manufacturer/product_class
rg_conf_print manufacturer/model_number
rg_conf_print manufacturer/hardware/serial_num
rg_conf_print cwmp/acs_url
rg_conf_print cwmp/username
rg_conf_print_obscure cwmp/password
rg_conf_print cwmp/conn_req_username
rg_conf_print_obscure cwmp/conn_req_password
¾ To change a TR-069 parameter, use the following API:
rg_conf_set manufacturer/vendor_name CompanyName
rg_conf_set manufacturer/vendor_oui 12AB56 (Organizationally
Unique Identifier; AudioCodes' OUI is 00908F)
rg_conf_set manufacturer/product_class MP-20X
rg_conf_set manufacturer/model_number MP-20X
rg_conf_set manufacturer/hardware/serial_num 123456
rg_conf_set cwmp/acs_url http://acsurl.com
rg_conf_set cwmp/username cpe
rg_conf_set_obscure cwmp/password 123456
rg_conf_set cwmp/conn_req_username acl
rg_conf_set_obscure cwmp/conn_req_password 123
¾ If a parameter is changed, activate the following CLI commands:
rg_conf_set cwmp/enabled 1
reconf 1
¾ To stop and restart the TR-69 client, use the following CLI
commands:
cwmp_session_start
cwmp_session_stop
Table 11-1: TR-069 Parameter Descriptions
Name Type Description
Manufacturer String(64) Manufacturer of the device (for display only).
OUI String(6) Organizationally unique identifier of the device
manufacturer. Represented as a six
hexadecimal-digit value using all upper-case
letters and including any leading zeros. The
value MUST be a valid OUI.
ProductClass String(64) Identifier of the class of product for which the
serial number applies. That is, for a given
manufacturer, this parameter is used to identify
the product or class of product over which the
parameter SerialNumber is unique.
SerialNumber String(64) Identifier of the particular device that is unique
for the indicated class of product and
manufacturer.

Table of Contents

Other manuals for AudioCodes MP-202

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MP-202 and is the answer not in the manual?

AudioCodes MP-202 Specifications

General IconGeneral
ModelMP-202
CategoryAdapter
Ports2 FXS ports
Protocol SupportSIP, H.323
Weight0.5 kg
Operating Temperature0°C to 40°C
Storage Temperature-20°C to 70°C
Humidity10% to 90% non-condensing
Network Interface10/100Base-T Ethernet
Voice CodecsG.711, G.729, G.723.1, G.726
SecurityHTTPS, TLS, SRTP
ManagementWeb-based, SNMP
Power Supply12V DC