C0-12DD1E-1-D β 4 DC Input (Sink/Source)/4 Sinking DC Output;
4 Analog Current Input
2 Analog Current Output Micro PLC
RS-485
+
_
LG
LNK/ACT
PORT1
PWR
RUN
ERR
RUN
STOP
PORT2
PORT3
RS-232
TX2
RX2
100MBIT
ETHER
NET
TX3
RX3
L
P
RT2
TX
-
T
R
NK
A
P
RT
R
ER
C0-12DD1E-1-D
C1
X1
X2
X3
X4
C2
Y1
Y2
Y3
Y4
+V
ACOM
AD1 I
AD2 I
AD3 I
AD4 I
DA+V
DA1 I
DA2 I
ACOM
+
+
24VDC
5 - 27
VDC
+
+
L
24
VDC
L
L
L
+
Transmitter 0-20mA
Transmitter 0-20mA
Transmitter 0-20mA
Transmitter 0-20mA
24VDC
+
Transmitter P/S
Wiring Diagram
See Discrete I/O Specifications
Inputs (X1 β X4) High-Speed
See Discrete I/O Specifications
Outputs (Y1 β Y4)
See Analog I/O Specifications
Current
Inputs (AD1I β AD4I)
See Analog Specifications
Current
Outputs (DA1I β DA2I)
NOTE: Please refer to the Analog I/O Conο¬guration section in Chapter 3 for information on using the
analog I/O.
NOTE: There are no ZIPLink pre-wired PLC connection cables and modules for the Ethernet Analog PLCs
(cannot mix discrete I/O and analog I/O signals in a ZIPLink cable).
WARNING: When using an Ethernet Analog PLC
unit, you must use CLICK programming software
version V2.20 or later.
General Specifications
Current Consumption at 24VDC
140mA
Terminal Block Replacement Part No.
C0-16TB
Weight
5.08 oz
(144g)
CLICK PLC Hardware User Manual, 6th Edition, Rev. G β C0-USER-M
2β88
Chapter 2: Speciο¬cations