9328900990 Rev L BE1-951 Introduction v
Application Firmware
Version and Date
Change
2.52.02, 04/02
Added Reset capability of the BKR OPCNTR when HMI is on Screen
4.3.1.
Enhanced reporting of the firmware version and increased number of
relay ID characters.
2.52.01, 10/01
Added real-time clock with 8 hour capacitor backup on all BE1-951
version 2 relays.
Added support for 4,000 point load profile demand log.
1.51.00, 03/01
Added the 32 overpower element.
Added the 159X auxiliary overvoltage element.
Added the 86 and 186 virtual lockout switches.
Updated the 25 Sync Check so that when operating in FG>BF mode,
a minimum slip frequency is required for a sync output.
Updated the 67 function to be user selectable for reference and
tripping elements.
The relay now performs a 2-cycle pre-dropout fault recording for use
when the BE1-951 does not trip.
Removed the 79F logic bit (bit 29 in the logic variable status report)
and replaced it with 79RST.
1.50.02, 08/00
Corrected bug in 25VM, Sync Check Voltage Monitor function logic.
Revised the 60FL, VT Fuse Loss function logic. The old algorithm
required breaker status to be TRUE (“closed”) to enable the function.
Corrected the bug in automatic setting group selection associated
with changing groups based upon recloser shot counter.
Revised target display function for the front panel HMI to include
Distance to Fault.
1.50.01, 06/00
Revised 60FL function. Reduced fixed time delay from 100 ms to 50
ms and coordinated order of processing of this function with voltage
tripping functions that it supervises.
Revised the 81, Over/Underfrequency function logic. (The old
algorithm allowed a trip on two consecutive cycles beyond the
threshold setting.)
Revised DNP protocol to pass level 2 compliance testing.
1.02.02, 04/00
This version was released after release of version 1.50.00, which was
a major upgrade in functionality for the relay. This version was
released to correct bugs in the original functionality and was mailed to
all purchasers of the BE1-951.
Revised power fail recovery logic and self-diagnostics function to
prevent inadvertent resets of the microprocessor when operated on
marginal AC power supply source.
Corrected bugs in Modbus protocol.
Revised the COMTRADE oscillographic download function to prevent
an invalid COMTRADE file from being created if the oldest record is
being overwritten by a trigger in the middle of the process of
transferring the file.