A 1.6 Safety information
The safety relevant information in accordance with DIN EN 294,
DIN EN 349 and the industry specific safety regulations must be
taken into consideration when installing the BST equipment in the
production machine, these include:
• There must be a safe distance between the BST equipment and
the machinery already installed on-site, such as machine
panels, building structure, etc.
• The interconnecting lines between the control equipment and the
control components or edge sensors must be laid so that nobody
can trip over them, they are not taught and they are well
anchored.
• Ensure that there is sufficient free headroom.
If the free passage is restricted, the relevant building
components causing the restrictions must be padded and a
danger warning signs must be attached to them (yellow/black).
Only trained specialist personnel are permitted to
undertake the assembly, installation and
commissioning!
Before starting work, ensure the equipment is
electrically isolated. To this end always carry out the
following measures:
1. Switch off
2. Prevent switching back on.
3. Check the equipment is isolated.
4. Earth.
5. Cover or shield any adjacent parts that are still live.
The mains power must always be switched off before
the equipment is opened.
If it becomes necessary to work on the open equipment
with voltage applied, then only Protection class IP 20 is
provided.
There is always increased danger because of the mains
voltage!
Do not use the chassis or machine frame as a climbing
aid or a stepladder.
Do not remove any of the safety devices.
Positioning movements will be undertaken by the
actuator during functional testing away from the
production machine and/or during the commissioning!
The relevant safety arrangements must implemented
during performance checks!
Monitor the overall safety concept of the production
machine during commissioning!
• Any transport safety devices that were used must be removed
prior to commissioning.
A 1.7 Emissions
The A-rated equivalent continuous sound level of the equipment is
less than 70 dB(A).
!
!
!