Commissioning example D 3
ekrPro Com
60
web guide controller EDV-No.: MD.191.01.05/1.6.x Appendix: D2
with analog sensors Date: 23.11.2007 Page: 3/4
D 3.4 Initial startup with sensor
positioning device FVGPro 2/MK
1. Carry out electrical connections as specified in the circuit diagram.
2. Reset the parameters to the works settings.
To do this open the “Sel.Std.System” menu and select F1 („Def.“).
The ekrPro Com
60
carries out a restart.
3. Select standard system
Now select a standard system which corresponds as closely as
possible to that you are using.
To do this, call up the "Sel.Std.System“ menu again and select the
appropriate system from the option list. Press key F2 ("set") to
activate this setting.
4. Check the actuator and the servo-center component connected.
4.1 Check actuator connected and readjust it if necessary.
4.2 Check sense of rotation.
Press the F2-key. The guiding frame must move in the
direction of sensor 1. If this is not the case, activate ‘Inv.’ and
repeat the adjustment.
4.3 Check the servo-center component.
If a servo-center component is fitted, the value of the
percentage display must decrease if the actuator moves to the
left (using key F2). If not, activate ‘Inv.’.