Operation C 2
ekrPro Com
60
web guide controller EDV-No.: MD.191.01.05/1.6.x Chapter: C 2
with analog sensors Date: 23.11.2007 Page: 9/19
Allocation of the change-over options to the operating modes
available options for the digital inputs
FVG mode
available options for the
keyboard arrow keys
terminal 80 = Low terminal 80 = High
Operating mode AUTO
not
connected
w
switch over via SETUP button
x
p
w w
FVG eco
w
switch over via SETUP button
x
p
switch over via SETUP button
FVG
w FVG
FVG 1MK
with centreline guiding
w
switch over via SETUP button
x
p
with edge guiding
x
p
switch over via SETUP button
FVG
w
(with centreline guiding)
FVG
(with edge guiding)
w
(with centreline guiding)
FVG
(with edge guiding)
FVG 2MK x
p
switch over via SETUP button
FVG
FVG FVG
Operating mode MAN
not
connected
mot
(actuator)
actuator actuator
FVG eco
mot
switch over via SETUP button
FVG
actuator actuator
FVG 1MK
mot
(actuator)
actuator actuator
FVG 2MK
mot
(actuator)
switch over via SETUP button
FVG1
switch over via SETUP button
FVG2
actuator actuator
The w-setting via EFE has priority with active
electronic remote fine adjustment device.
w = set value
x
p
= gain
FVG = sensor positioning device