Terminal diagrams / Service displays B 4
ekrPro Com
60
web guide controller
EDV-No.: MD.191.01.05/1.6.x Appendix B 4
with analog sensors Date: 23.11.2007 Page: 7/9
B 4.2.13 Terminal strip X16; Analog output and tacho input:
Terminal
X16
Signal Remarks
68 GND GND for analog output
69 Output ±10V Analog output for external
motor output stage.
Not for direct connection of hydraulic
components SV1 …, HR 024,
HR 040, EH-St 9/3.
(see terminals 42-43)
70
Currently not used.
71
Currently not used.
B 4.2.14 Terminal strips X17, X18, X19; Power supply (24V output for camera)
Plug Plug Terminal
X17,
X18,
X19
Function Remarks
Pin 1 + 24V
Pin 2 Not used
X70
X71
Pin 3 GND
The ekrPro Com
60
control unit is itself protected
against incorrect wiring (connection with reverse
polarity).
If the supply voltage was inversely connected to
the control unit, this reverse polarity would also
be connected to the 24 V output socket.
This could lead to damage to components
connected to this socket.