B 3.7.5.9.3 Truth table
Default values for digital input allocation: Dig. InTable 1
Terminal
Line Significance 85 84 83 82 81 80 79 78 77 76 75 74
1 set Auto
(automatic mode)
X X X X X X X X X
1 0 0
2 set MAN
(manual mode)
X X X X X X X X X
0 0 1
3 set SC
(servo center position)
X X X X X X X X X
0 1 0
4 opmode clear
(defined zero state operating mode)
X X X X X X X X X
0 0 0
5 set Edge1
(edge 1)
X X X X X X
0 0 1
X X X
6 set Edge2
(edge 2)
X X X X X X
0 1 0
X X X
7 set Center1&2
(center 1/2)
X X X X X X
0 1 1
X X X
8 set Edge3
(edge 3)
X X X X X X
1 0 0
X X X
9 set Edge3 Inv. (inverse edge 3)
X X X X X X
1 0 1
X X X
10 guid.mode clear
(defined zero state guiding mode)
X X X X X X
0 0 0
X X X
11 Motor stop
X X X
0 0 0
X X X X X X
12 Motor stop
X X X
0 0 1
X X X X X X
13 FVG stop
X X X
0 0 0
X X X X X X
14 FVG stop
X X X
0 0 1
X X X X X X
15 Motor left
X X X
0 1 0
X X X X X X
16 FVG left
X X X
0 1 1
X X X X X X
17 Motor right
X X X
1 0 0
X X X X X X
18 FVG right
X X X
1 0 1
X X X X X X
19 Motor stop
X X X
1 1 0
X X X X X X
20 FVG stop
X X X
1 1 1
X X X X X X
21 Set Lim.Sw. 1
(stop switch 1)
X
1 0
X X X X X X X X X
22 Reset Lim.Sw. 1
(reset stop switch 1)
X
0 0
X X X X X X X X X
23 Reset Lim.Sw. 1
(reset stop switch 1)
X
1 1
X X X X X X X X X
24 Set Lim.Sw. 2
(stop switch 2)
X
0 1
X X X X X X X X X