Commissioning example D 3
ekrPro Com
60
web guide controller EDV-No.: MD.191.01.05/1.6.x Appendix: D2
with analog sensors Date: 23.11.2007 Page: 2/4
D 3.2 Start-up an actuator
with OMG 4 / 7 / 8
1. Wire in the motor and servo-center component as shown in the circuit
diagram.
2. Go to General Setup > Actuator > Type (EMS&Hydr.) and select
the actuator. All of the actuators present can be activated from the
options list.
3. Go to General Setup > Actuator > SC-Transducer > Type & Dir.
and select and enter the servo-center component.
4. Check the actuator positioning movement.
Does the actuator move into the centre position?
Yes = no alterations required
no = activate “Inv“ checkbox (x)
5. Go to General Setup > Actuator > SC-Transducer > SC W & XP
and set the gain for the servo-center component.
D 3.3 Start-up an actuator
without a servo-center component
1. Wire the motor as shown in the circuit diagram.
2. Go to General Setup > Actuator > Type (EMS&Hydr.) and select
the actuator.
All of the actuators present can be activated from the options list.
3. Go to General Setup > Actuator > SC-Transducer > Type & Dir.
and deactivate the servo-center component, i.e. select and enter
“not connected“ in the options list.