Disassembly & Assembly Disassembly 168
3. Remove four serews securing the PF Base.
Figure 4-125.
4. Remove the Grid Spacer and the Grid End.
Figure 4-126.
5. While holding down the PF Encoder from inside, remove two screws and remove
the PF Encoder.
Figure 4-127.
PF base
Screws
Grid end
Grid spacer
C A U T I O N
When assembly, attach the PF encoder after plug the Scale, PF to
the sensor department of the PF encoder.
Do not scars and touching the Scale, PF.
When assembly, attach the grid end after two places of bosses are
combined with the hole of the PF base.
The grid spacer have to be set to the direction that has a ditch
side.