EPSON Stylus Pro 10000/10000CF/10600 Revision D
Adjustment Mechanism Adjustment 199
5.3.8 Offset adjustment for dot missing detector
Automatically offset values are fixed after the dot missing detection operation. Refer to
the paragraph "Offset adjustment for dot missing detector" on page 199 for details.
5.3.8.1 P_Front/Rear/Edge sensor adjustment
Adjustment procedure
1. Remove the Option I/F Cover from the rear of the printer.
2. Start Diagnostic Mode 1, perform volume adjustment for "Test" - "Sensor" -
"Edge AD, Front AD, Rear AD" corresponding sensors using special purpose
paper. See "Sensor" on page 210 for details.
Figure 5-9.
*: Blight Recycle Paper (XEROX) is soled in japanese market only.
FRONT/REAR SENSOR
Adjustment procedure
1. Adjust so that On-Off (left value) is within the adjustment range.
2. With paper set in position, confirm that the value for On (right value) is within the
adjustment range.
EDGE SENSOR
Adjustment procedure
1. Adjust so that On (right value) is within the adjustment range.
2. With paper set in position, confirm that the value for On-Off (left value) is within
the adjustment range.
<Tools and Equipment>
Precise standard screwdriver (1mm width)
Special purpose paper Bright Recycle A3 (Fuji Xerox)
Microtrace #300 LMB A3 (Kimoto)
VR4
VR1
VR6
VR3
VR2
VR5
FRONT: VR2, VR5
REAR: VR1, VR4
P_Edge: VR3, VR6
VR1, 2, 3: Rough adjustment
VR4, 5, 6: Fine adjustment
Table 5-5. FRONT/REAR/P_Edge Sensor adjustment
Sensor Adjustment sheet Left (ON-OFF) Fine adjustment
P_Front
KIMOTO #300
Tracing Paper
040-05E 05E-080
P_Rear
KIMOTO #300
Tracing Paper
040-05E 05E-080
P_Edge
Blight Recycle Paper
(XEROX)*
0B0-0CF 0C0-0CF
C A U T I O N
If the precise standard screwdriver contacts the rear panel, a
correct value cannot be read.
Thank You For Using TheServiceManualShop.com