EPSON Stylus Pro 10000/10000CF/10600 Revision D
Disassembly & Assembly Disassembly 176
6. Remove a right side edge screw (M3x6), then remove the Scale, CR.
Figure 4-147.
4.3.3.19 Removing the Paper Hold Solenoid
1. Remove the R Side Cover as described in 4.3.1.4 "R Side Cover Removal".
2. Remove the L Side Cover as described in 4.3.1.5 "L Side Cover Removal".
3. Remove the H Top cover as described in 4.3.1.3 "H Top Cover Removal".
4. Remove the Cleaning Unit, the Flushing Box and the Dot Missing Detedtor.
(Refer to 4.3.3.13 "Removing the Pump Cap Unit" /4.3.3.14 "Removing Flushing
Box" / 4.3.3.15 "Removing Dot Missing Detector")
5. Disconnect Paper Hold Solenoid connector at R side frame cable pit hole.
Figure 4-148.
C A U T I O N
Be careful to prevent oil applied to CR Rail from adhering to
Scale, CR.
When assemble, Adjust the positions of 7 Scale, CR hold, so that
the Scale, CR becomes a straight line.
Screw
Scale, CR
Paper hold solenoid
Cable connector