EPSON Stylus Pro 10000/10000CF/10600 Revision D
Adjustment Self-Diagnostics 233
5.4.4.8 A123 slant adjustment
Print the test pattern and make sure the print quality by referencing the Figure 5-58.
If the slant condition is presented, perform the mechanical adjustment.
This test using A1, A2 and A3 nozzle.
Figure 5-57 showing menu sequence.
Figure 5-57.
<Print sample>
1. Check items: Black lines, Light Cyan lines and Magenta lines are continue as same
level by a magnifying glass with scale.
2. Printing method.
One pass with Uni-D at 360dpi resolution for CR and 45dpi for PF.
Figure 5-58.
Item
SelecType
SelecType
Enter
Printing Pattern
Adjust the slant?
Wait a moment
Wait a moment
End with "Pause" key.
Output Pattern
A13 Slant Check End
Shift to "A123 Slant Check End"
menu by pressing "Pause" key.
Shift to "B123" or "A123" slant
check menu with following key
operation.
"Enter" key: B123 slant check.
"Pause" key: A123 slant check.
Shift to"A123" slant check menu
with "Pause" key.
Print out the pattern with "Enter"
key.
Print END
CR movement END
Pause
CR movement END
K
LC M MLCK
When check the slant, regard the
joint department shown here.
Thank You For Using TheServiceManualShop.com