EPSON Stylus Pro 10000/10000CF/10600 Revision D
Disassembly & Assembly Disassembly 184
4.3.3.28 Removing the P_THICK Sensor
1. Remove the H Top Cover as described in 4.3.1.3 "H Top Cover Removal".
2. Push the Paper Hold Lever to the front. (Unlock condition)
Figure 4-168.
3. Marking the P_THICK sensor bracket position on the CR Guide Rail.
Figure 4-169.
4. Remove two screws (M3x6) securing the P_THICK Sensor.
Figure 4-170.
5. Disconnect the cable connector from the P_THICK Sensor.
Figure 4-171.
Paper hold lever
P_THICK sensor
Marking
CR guide rail
P_THICK sensor
Screws
Cable connector