EPSON Stylus Pro 10000/10000CF/10600 Revision D
Adjustment Self-Diagnostics 260
5.4.8.5 Head Up / Down
Perform the head up / down reliability test.
Perform the capping designated number.
When the reliability number is [-1], reliability is repeated until [Pause] key is input.
When the reliability number is [-1], the biggest count number is 99,999,999 times
(within 8 column), and the count become 0 in the case that this is exceeded.
Moving the carriage and combine the meshing of the gear.
Figure 5-97 showing the head up / down reliability test menu sequence.
Figure 5-97.
The maximum value of the reliability number designation is [99,999,999 times].
The maximum value of the wait time is [999 seconds].
There is the wait time that is designated whenever the head up / down reliability
test ends 1 time.
5.4.8.6 Head lock
Perform the head lock reliability test.
Perform the head lock (cancel / set) designated number.
When the reliability number is [-1], reliability is repeated until [Pause] key is input.
When the reliability number is [-1], the biggest count number is 99,999,999 times
(within 8 column), and the count become 0 in the case that this is exceeded.
Figure 5-98 showing the head lock reliability test menu sequence.
Figure 5-98.
The maximum value of the reliability number designation is [99,999,999 times].
The maximum value of the wait time is [999 seconds].
There is the wait time that is designated whenever the head lock reliability test
ends 1 time.
Enter
Enter
Enter
Life Count : -1
Wait Time (Sec).0
Count : 10
End : 50
Adjustable with "Paper Feed +/-" key.
Adjustable with "Paper Feed +/-" key.
Enter
Enter
Enter
Life Count : -1
Wait Time (Sec).0
Count : 10
End : 50
Adjustable with "Paper Feed +/-" key.
Adjustable with "Paper Feed +/-" key.