EPSON Stylus Pro 10000/10000CF/10600 Revision D
Adjustment Mechanism Adjustment 197
7. Turn on the printer power and implement and confirm the paper cut operation.
Figure 5-4.
5.3.5 Front cover sensor adjustment
The following adjustment with the self-diagnostic function is performed for completed
operations related to replacement or removal of Front Cover/Front Cover sensors.
Standard value
Determines whether a finger enters into the front cover or not.
Cover open: The position whether a finger enters into the front cover or not.
Cover close: The position which a finger enters into the front cover.
Adjustment procedure
1. Start the self-diagnostic mode and set "Test: Sensor"-"front cover sensor".
2. Lightly fasten 2 screws securing the Left and right front sensors and adjust the
sensor On/Off position by moving the Front Cover up and down.
Figure 5-5.
C A U T I O N
Do not move the cutter up/down except on the Sub-Platen. If above
caution is not followed, the cutter blade is damaged.
L Type adjusting tool