EPSON Stylus Pro 10000/10000CF/10600 Revision D
Adjustment Self-Diagnostics 255
5.4.7.3 Parameter display
Display the parameter of designated address.
Figure 5-90 showing the parameter display menu sequence.
Figure 5-91.
5.4.8 Reliability Test
Perform the reliability test of the mechanism and the head.
Table 5-18 showing the items.
Figure 5-92 showing the reliability test menu sequence.
Item
SelecType
Enter
Address : 0
0 0 0
Address : 0 0
0 0
Address : 0 0 0
0
Address : 0 0 0 0
0000 : 0
Adjustable with
"Paper Feed +/-"
key.
Enter
Enter
Enter
Item
Item
Item
SelecType
SelecType
SelecType
Adjustable with
"Paper Feed +/-"
key.
Adjustable with
"Paper Feed +/-"
key.
Adjustable with
"Paper Feed +/-"
key.
Table 5-18. Reliability test
Item Description
CR Motor Bi-D carriage movement
PF Motor Drive PF roller.
CR+PF Motor CR and PF operation at same time.
Cutter Paper cut
Head Up/Down Continuous head Up/Down.
Head Lock Continuous head lock and release.
Lever Lock Continuous lever lock and release.
Cleaning Cleaning
Print Reliability Continuous printing
Shutter Shutter reliability
Total reliability CR,PF,CR+PF, Head Up/Down, Cutter solenoid.
Reliability confirmation Confirm the number of reliability test.
Thank You For Using TheServiceManualShop.com