EPSON Stylus Pro 10000/10000CF/10600 Revision D
Adjustment Self-Diagnostics 262
5.4.8.9 Print
Perform the print reliability test.
Perform the pattern print designated number.
When the reliability number is [-1], reliability is repeated until [Pause] key is input.
When the reliability number is [-1], the biggest count number is 99,999,999 times
(within 8 column), and the count become 0 in the case that this is exceeded.
Figure 5-101 showing the print reliability test menu sequence.
Figure 5-101.
The maximum value of the reliability number designation is [99,999,999 times].
5.4.8.10 Shutter
Perform the shutter reliability test.
Perform the shutter actuation designated number.
When the reliability number is [-1], reliability is repeated until [Pause] key is input.
When the reliability number is [-1], the biggest count number is 99,999,999 times
(within 8 column), and the count become 0 in the case that this is exceeded.
Figure 5-102 showing the shutter reliability test menu sequence.
Figure 5-102.
Where the shutter is transited ("closing condition"-> "Half open condition" ->
"Full open condition"), the reliability number is counted up of 1 time.
The maximum value of the reliability number designation is [99,999,999 times].
Enter
End : 50
Count : 10
Cut : on
Clear Print Cnt?
Print Counter :
Adjustable with "Paper Feed +/-" key.
Change the ON/ OFF with "Paper
Feed +/-" key.
Clear with "Enter" key.
Cancel with "Pause" key.
Enter
Enter
Enter
End : 50
Life Count : -1
Count : 10
End : 50