EPSON Stylus Pro 10000/10000CF/10600 Revision D
Disassembly & Assembly Disassembly 175
6. Remove five screws (M4x8) securing Ink Pump ASSY, then remove it.
Figure 4-144. Air tube location
4.3.3.18 Removing the Scale, CR
1. Remove the R Side Cover as described in 4.3.1.4 "R Side Cover Removal".
(Remove without forgetting H Top Cover.)
2. Remove the L Side Cover as described in 4.3.1.5 "L Side Cover Removal".
3. Marking 7 place of the Scale, CR hold position.
4. Loosen by 2 rotations the screws at Scale, CR Hold brackets (7 locations, 2 screws
each). Move the Scale, CR Hold brackets to topmost position and temporarily
secure screws.
Figure 4-145.
5. Remove the Tention Spring of the left side edge.
Figure 4-146.
12
3
65
4
123
456
Black
Cyan
Magenta
Yellow
Light Magenta
Light Cyan
Ink cartridges rear view
Installation position of air tubes (6) is shown in the diagram above, but installation in any
position is acceptable.
Scale, CR hold
Screws
Tention spring
Scale, CR