EPSON Stylus Pro 10000/10000CF/10600 Revision D
Disassembly & Assembly Disassembly 162
4.3.3.7 Removing the CR Encoder Sensor
1. Remove the R Side Cover.
2. Remove the H Top Cover.
3. Remove the Carriage Cover.
4. Disconnect the CR Encoder cable connector from Head Board.
5. Remove two screws (CPP: M3x8) securing the CR Encoder Sensor, then remove
the CR Encode Sensor.
Figure 4-110. CR Encoder Sensor Removal
4.3.3.8 Removing the P_Edge Sensor
1. Remove the R Side Cover.
2. Remove the H Top Cover.
3. Remove the Carriage Cover.
4. Disconnect the P_Edge Sensor cable connector from Head Board.
5. Remove one screw (CBP: M3x6) securing the P_Edge sensor and remove the
sensor.
Figure 4-111. P_Edge Sensor Removal
C A U T I O N
When disassemble or reassemble the unit, do not bend or damage
the Scale, CR.
A D J U S T M E N T
R E Q U I R E D
When the CR Encoder Sensor or Scale, CR has been replaced or
removed, use the CR_ENC installation gauge to adjust the
installation position. (Refer to Chapter 5 "Adjustment," section
5.3.6)
Scale, CR
CR encorder sensor
Screws
C A U T I O N
When reassembling the sensor, combine the boss location of the
hole of the head base and P_EDGE sensor.
Fix P_EDGE sensor while pushing it towards the platen.
P_Edge sensor
Screw
Thank You For Using TheServiceManualShop.com