EPSON Stylus Pro 10000/10000CF/10600 Revision D
Adjustment Self-Diagnostics 263
5.4.8.11 Total reliability
Perform the CR axis (motor, bearing, tube etc.), the PF axis, the CR axis + the PF axis,
the head up / down motor, the head lock, and the cutter solenoid simultaneous
reliability test.
When the reliability number is [-1], reliability is repeated until [Pause] key is input.
When the reliability number is [-1], the biggest count number is 99,999,999 times
(within 8 column), and the count become 0 in the case that this is exceeded.
Following figure showing the total reliability test menu sequence.
Figure 5-103.
As for the parameter of CW, [240CPS], [300CPS], [400CPS] and [800CPS] are
possible select.
As for the parameter of CCW, [240CPS], [300CPS], [400CPS] and [800CPS] are
possible select.
In the case that the parameter of CW is [off], the CCW parameter input screen is
skipped.
The maximum value of the paper feed is [100.0mm].
The maximum value of the CR + PF reliability number is [999 times].
The maximum value of the reliability number designation is [21,600 times].
Carriage migration MAX location is 738.06 mm from the starting point location.
Carriage migration MIN location is 111.05 mm from the starting point location.
When the [Pause] key is pushed during the reliability test, the test can be broken.
Table 5-20 showing the default value of total reliability test.
Enter
End : 100
Count CR PF : 50
Life Count : -1
CR+PF Motor : 100
Speed CW :240CPS
Speed CCW :240CPS
Feed Amount : 3.0mm
Count CR PF : 10
Adjustable with "Paper Feed +/-" key.
Adjustable with "Paper Feed +/-" key.
Adjustable with "Paper Feed +/-" key.
Adjustable with "Paper Feed +/-" key.
Adjustable with "Paper Feed +/-" key.
Enter
Enter
Enter
Enter
Table 5-20.
Item Default value
CW speed 240 CPS
CCW speed 240 CPS
Feed amount 3.0mm
CR + PF count 500
Life count -1
Thank You For Using TheServiceManualShop.com
Thank You For Using TheServiceManualShop.com