EPSON Stylus Pro 10000/10000CF/10600 Revision D
Disassembly & Assembly Disassembly 167
4.3.3.12 Removing the PF Encoder
1. Disconnect the PF Encoder cable connector.
Figure 4-123.
2. Loosen the set screw (2mm), and remove the bearing stopper.
Figure 4-124.
C A U T I O N
When removing PF Motor, be careful not to allow motor pinion
(metal gear) to be damaged by contacting frame.
When reassembling PF Motor, move the PF reduction pulley by
hand and visually confirm that PF timing belt stays evenly in
center of pulley.
Figure 4-122.
A D J U S T M E N T
R E Q U I R E D
When PF Motor has been removed or PF timing belt tension
changed, perform belt tension adjustment. (Refer to Chapter 5,
section 5.3.2)
Scale, PF
Steel belt
Timing belt
PF reduction
pulley
Cable connector
Bearing stopper