EPSON Stylus Pro 10000/10000CF/10600 Revision D
Disassembly & Assembly Disassembly 174
4.3.3.16 Removing the Shutter Motor
1. Remove the Flushing Box as described in 4.3.3.14 "Removing Flushing Box".
2. Remove the Rear Cover as described in 4.3.1.7 "Rear Cover Removal".
3. Disconnect the cable connector connected to CN14 on the C362DRV Board.
Figure 4-140.
4. Marking the Shutter Motor securing position.
5. Remove two screws securing the Shutter Motor, then remove it.
Figure 4-141.
4.3.3.17 Removing the Ink Pump ASSY
1. Remove the Pump Cap Unit as described in 4.3.3.13 "Removing the Pump Cap
Unit".
2. Remove the Rear Cover as described in 4.3.1.7 "Rear Cover Removal".
3. Disconnect the cables of the Air Release Plunger and Ink Pump Motor from CN11
/ 25 connectors on the C362DRV Board, and take the cable out from the hole in
the R Side Frame.
4. Disconnect the cable connector from the Dot Missing Detector Unit and the Lock
Lever Sensor.
Figure 4-142.
5. Pick the six tubes from the air distributor.
Figure 4-143.
C A U T I O N
When removing/replacing Shutter Motor, perform the backlash
adjustment for drive gear of shutter mechanism. (Refer to Chapter
5.)
Shutter motor
Cables
(connected to
CN14 on the
C362DRV board)
Shutter motor
Screws
Dot missing
detector unit
Air release
plunger cable
Ink motor cable
Ink pump motor
Screws
Screws
Air distributor