EPSON Stylus Pro 10000/10000CF/10600 Revision D
Adjustment Self-Diagnostics 261
5.4.8.7 Lever lock
Perform the lever lock reliability test.
Perform the lever lock (cancel / set) designated number.
When the reliability number is [-1], reliability is repeated until [Pause] key is input.
When the reliability number is [-1], the biggest count number is 99,999,999 times
(within 8 column), and the count become 0 in the case that this is exceeded.
Figure 5-99 showing the lever lock reliability test menu sequence.
Figure 5-99.
The maximum value of the reliability number designation is [99,999,999 times].
The maximum value of the wait time is [999 seconds].
There is the wait time that is designated whenever the lever lock reliability test
ends 1 time.
5.4.8.8 Cleaning
Perform the cleaning reliability test.
Perform the cleaning designated number.
When the reliability number is [-1], reliability is repeated until [Pause] key is input.
When the reliability number is [-1], the biggest count number is 99,999,999 times
(within 8 column), and the count become 0 in the case that this is exceeded.
Figure 5-100 showing the cleaning reliability test menu sequence.
Figure 5-100.
As for the parameter of cleaning kind, [CL1], [CL1’], and [CL2] are possible
select.
The maximum value of the reliability number designation is [99,999,999 times].
The maximum value of the wait time is [999 seconds].
There is the wait time that is designated whenever the cleaning reliability test ends
1 time.
Enter
Enter
Enter
End : 50
Life Count : -1
Wait Time(Sec).0
Count : 10
Adjustable with "Paper Feed +/-" key.
Adjustable with "Paper Feed +/-" key.
Enter
End : 50
Life Count : -1
Wait Time (Sec). 0
Count : 10
Cle. Prm. CL1
Adjustable with "Paper Feed +/-" key.
Adjustable with "Paper Feed +/-" key.
Adjustable with "Paper Feed +/-" key.
Enter
Enter
Enter