EPSON Stylus Pro 10000/10000CF/10600 Revision D
Adjustment Self-Diagnostics 230
5. Horizontal nozzle lineup confirmation
It prints it in the order of Black/Cyan/Magenta/Yellow/Light Magenta/Light Cyan
from the left.
Figure 5-50.
6.Vertical nozzle lineup confirmation.
It prints in the order of Black/Cyan/Magenta/Yellow/Light Magenta/Light Cyan
from the left.
Figure 5-51.
5.4.4.5 Offset Adjustment
Perform the dot missing detection and adjust the offset value automatically.
1. Move to Adjustment mode in the self-diagnostics.
2. Select Paper Source or SelecType switch to the Offset Adjustment, and then push
Enter key to enter offset adjustment.
3. The printer performed offset adjustment automatically and display the result as
following.
Figure 5-52.
The display digit showing in the order of AGC threshold value/DAC max/and DAC
mini. from the left.
C A U T I O N
The offset adjustment will not be performed when Auto nozzle
check setting is OFF in the maintenance mode.
C H E C K
P O I N T
The AGC threshold value are 2208 or more. If the value is less
than 2280, the detector will judge the no dot missing even if the
dot missing happen.
DAC: D/A convertor
DAC max. : Maximum input value of detector at dot missing
detection.
DAC min. : Minimum input value of detector at dot missing
detection.
AGC threshold
DAC max.
DAC mini.
Wait
Res : 2640 2640 2384