Disassembly & Assembly Disassembly 170
7. While supporting the Pump Cap Unit from the rear by hand, remove 2 screws
(M4x8) securing the Pump Cap Unit to the CR Guide Rail.
Figure 4-131.
C A U T I O N
Use a magnetic tip screwdriver when removing/installing screws
and be careful of the following points.
1. Do not drop screws inside CR Guide Rail. (Difficult to see inside
rail.)
2. Do not damage steel belt.
Do not touch the cleaner head and the cap.
Figure 4-132.
CR Guide rail
Cleaning Unit
Screws
Bracket
Cap motor
Cap
Cleaner head