Current consumption, standby Typ. 17 mA at 12 V DC
Max. 25
mA
Output current per "GE" connec-
tion
Nom. max. 0.5 A
Output current per "FE" connec-
tion
Nom. max. 2 A
Energy management On/Off with start/stop of Ethernet traffic
(On/Off upstream module)
Protection Protection against reverse polarity, overload
protection
Overvoltage category
(mains supply, IEC 60664-1)
II