Operating manual.
CNC 8060
CNC 8065
24.
DIAGNOSIS
Operating Terms.
·464·
(REF: 1807)
24.9.2 Enter the CNC code to activate or cancel the temporary user license.
The code to activate or cancel the temporary user license is entered during diagnosis mode,
in the "Software options", "Operating Terms” softkey section. If the CNC has the OEM
password, the CNC will request this password the first time that someone tries to enter the
code. The code can be entered with or without spaces.
One of the following two cases will occur when entering the new code:
• The code extends the period of the temporary user license. The code changes the final
license date and the remaining days.
• The code cancels the temporary user license.
If the user makes a mistake when entering the code, the CNC will report this and will request
the code again. The CNC will only allow three tries to enter the code per start-up; after the
three tries, the CNC must be turned off and turned back on again. The CNC will display a
message with the cause of the error.
• Wrong code. Type it again.
The user has entered the code incorrectly. Re-enter the code.
• Code generated wrong. Hardware ID does not match.
The hardware ID of the new code is not that of the machine; request a new code with
the correct hardware ID from the manufacturer.
• Code generated wrong. The OEM KEY does not match.
The OEM KEY of the new code is not the same as that used by the manufacturer when
"Operating Terms” where activated; request a new code with the correct OEM KEY from
the manufacturer.
• Code generated wrong. It must be a later date.
The new expiration date is not later than the current expiration date; request a new code
with the correct expiration date from the manufacturer.
• When activating the "Operating Terms" feature and entering the first code, the date on the CNC
must be correct.
• It is not possible to enter a final date older than the current one at the CNC.
When the OEM sends the “Operating Terms” code, it should also send the expiration date and the