RX2530 M4 Upgrade and Maintenance Manual 127
Power supply unit (PSU)
V CAUTION!
In case of not enough space at the under side, unlock the CMA
stopper of the server below and pull out the CMA to the rear side.
Ê Remove the CMA stopper with the mounted crossbar (see figure 40).
Ê Hold the CMA stopper, the crossbar and the CMA including cables in the one
hand.
Ê Remove the FJBU and install the new FJBU carefully.
Ê Mount the complete assembly (CMA stopper, the crossbar and the CMA)
again into the rail.
6.3.3.1 Preliminary steps
Ê "Locating the defective server" on page 47
6.3.3.2 Removing the defective FJBU
Ê Remove the FJBU, see "Removing an FJBU" on page 125.
6.3.3.3 Installing the new FJBU
Ê Install the FJBU, see section "Installing an FJBU" on page 124.
6.3.3.4 Concluding steps
Ê No steps needed.