RX2530 M4 Upgrade and Maintenance Manual 85
Basic software procedures
After replacing the front panel or Chassis ID EPROM
Ê Check the SEL log files as described in section "Viewing and clearing the
System Event Log (SEL)" on page 95 to verify whether a backup copy of the
system board settings has been transferred to the Chassis ID EPROM:
Chassis IDPROM: BMC FW backup successful
5.2.3 Updating expansion card firmware
I For Japan:
Follow the instructions provided separately.
After replacing the expansion card, it is essential to upgrade the firmware to the
latest version without connecting any storage devices. The latest expansion
card firmware version is available from the Fujitsu support web pages at:
http://ts.fujitsu.com/support/
For Japan:
http://www.fujitsu.com/jp/products/computing/servers/primergy/downloads/
I Note on the boot watchdog
Before updating expansion card firmware, ensure that the boot watchdog
is disabled, see section "Disabling the boot watchdog" on page 78.
After updating expansion card firmware, enable the boot watchdog
again, see section "Enabling the boot watchdog" on page 92.
I Fujitsu does not assume responsibility for any damage done to the
server or for the loss of any data resulting from firmware updates.
Using the ServerView Update Manager
For more information on how to update the expansion card firmware using the
ServerView Update Manager or Update Manager Express (UME), see the
following manuals:
ServerView Update Manager:
"ServerView Update Management" user guide
ServerView Update Manager Express:
"Local System Update for PRIMERGY Servers" user guide