52 Upgrade and Maintenance Manual RX2530 M4
Basic hardware procedures
Example HVDC PSU 380 V
Figure 4: Disconnecting the server from the dc voltage - example HVDC PSU 380 V
Ê Press the locking latch (A) of the power cord plug inside, until it disengages
(1).
Ê Disconnect the power cord from the PSU (2).
4.4 Getting access to the component
V CAUTION!
Only for non-hot plug components:
Before removing or attaching covers, turn off the server, all peripheral
devices, and any other connected devices. Because there is a risk of
electric shock or damage, please disconnect all power cords from the
outlet.
The top cover must be replaced as soon as possible for purposes of
cooling, to comply with EMC regulations (regulations regarding
electromagnetic compatibility) and to prevent fires.
For more information, see chapter "Important information" on
page 35.