D1 Servo Drive User Manual LCD Display
HIWIN MIKROSYSTEM CORP. 7-3
MD20UE01-2109
7.1.2 Description of operation page
There are four pages in the LCD display:
(1) Home page
(2) Display parameters page
(3) Change parameters page
(4) Actions page
Press F key to switch among modes. For the structure of the LCD display, please refer to figure 7.1.2.1.
Note:
The LCD display of CoE model only shows home page.
(1) Home page
The home page displays the enabling or disabling status of motor, error message, warning message
and axis name.
(2) Display parameters page
The display parameters page displays parameters, such as motor feedback position, position
command, position error, feedback velocity, velocity command, I/O status and motor status (phase
initialization, moving, homing and error map function).
(3) Change parameters page
Go to change parameters page to modify servo gain, velocity loop gain, operation mode, pulse type,
advanced parameters and save parameters from RAM to Flash.
(4) Actions page
Go to actions page to enable or disable motor, jog motor, move to absolute target position, clear
coordinates to 0, perform auto tuning and set motor model.