Servo Drive Configuration D1 Servo Drive User Manual
5-64 HIWIN MIKROSYSTEM CORP.
5.7 Save parameters to Flash and set to factory default
5.7.1 Save parameters to Flash
Click on (Save parameters from amplifier RAM to Flash) to save current parameters to Flash. The
parameters will still be accessible after the servo drive is turned off. Please pay attention to the following.
(1) Emulated encoder output is temporarily not available while saving parameters to Flash. Position
information during this time could be incorrect.
(2) Values for error map function will not be saved to Flash. Go to Error map setting page in Application
center to save error map settings to Flash.
5.7.2 Set parameters to factory default
Click on Tools on the menu bar and select Set parameters to factory default to set parameters to
factory default, as figure 5.7.2.1. Set drive to factory default window appears as figure 5.7.2.2
(Lightening version 0.180 to 0.185A). If user would like to clear error map table at the same time, please
select Clear error table in flash then reset drive and click on Yes button. When Clear error table in
flash then reset drive is selected, a message dialog shown in figure 5.7.2.3 will appear informing user
that before clearing error map table, the default settings will be saved to the servo drive and the servo
drive will be reset. Click on Yes button and the system will proceed accordingly. Click on No button to
return to Set drive to factory default window. After the parameters are set to factory default, the servo
drive will be automatically reset.
Figure5.7.2.1