Diagnostics 291
Pulse Type
Selects whether the signal that will be sent to the drive amplifier will be a single pulse or a repeated
pulse. If the repeated pulse is selected, the signal will continue until the Test soft key for that axis is
pressed again.
Pulse Direction
Selects whether the signal that will be sent to the drive amplifier will be a positive, negative or
alternating pulse.
Pulse Magnitude
Sets the voltage of the signal to be sent to the drive amplifier.
Pulse Duration
Sets the amount of time for each segment of the signal to be sent to the drive amplifier.
Test Transverse/Rail/Dual Gantry/CBH
The Test buttons will send the selected output signal to the appropriate drive amplifier. If a repeating
signal has been selected, any combination of available test buttons may be used for the test. Each
drive amplifier will be sent the selected output signal until the selected output soft key has been
pressed a second time to end the test.