Page #74 background image
Setups 50
Pulse On Time
When Automatic Pulse Mode is selected for pierce control the user can select Pulse On and Off Time
to adjust duty cycle response of the sensor pulses from the laser cutting head.
Pulse Off Time
When Automatic Pulse Mode is selected for pierce control the user can select Pulse On and Off Time
to adjust duty cycle response of the sensor pulses from the laser cutting head.
Creep Time
Specifies the amount of time after piercing the material that the laser head travels at Creep Speed for
cutting. Creep Speed is determined by a setup parameter in the Speed Setup Screen and is a
percentage of the programmed cut speed. After the Creep Time is completed, the control accelerates
to full cut speed.
Beam Off Time
The Beam Off Time parameter specifies the amount of time the beam output will be turned off prior to
he stop of motion. This feature can be used to tab parts for attachment to the skeleton.
Postflow Time
Specifies the amount of time that the cutting gas remains on after the cut is complete.
Cut Height
The Cut Height setup parameter is used to select the desired cut distance above the plate. This will
set the initial cut height before the laser cut motion is activated. Cut Height is derived from the CHS
signal and the calibration curve and represents cut distance from nozzle tip to the plate.
Pierce Height
The Pierce Height setup parameter is used to select the desired Pierce Height above the plate. This
can be entered as a multiplication factor that is calculated times the Cut Height or an actual Pierce
Height distance.
Lens Cut Position
Sets the focal lens position in the laser head for cutting.
Lens Pierce Position
Sets the focal lens pierce position in the laser head for cutting.
Pulse Laser Time
Sets the Laser Pulse Time duration for a one shot beam alignment.
Pulse Laser Power
Sets the Laser Pulse Power for a one shot beam alignment.

Table of Contents

Other manuals for Hypertherm MicroEdge

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm MicroEdge and is the answer not in the manual?

Hypertherm MicroEdge Specifications

General IconGeneral
BrandHypertherm
ModelMicroEdge
CategoryControl Systems
LanguageEnglish

Related product manuals