Edge Ti™ 510
Plasma Interface Assembly Mounting
Mount the plasma interface assembly close to the plasma power supply for easy connection of arc
voltage and signal wires between the units. The unit can be mounted in any position and can be
mounted directly to the back or inside of the power supply. The mounting holes are sized for #6 or
M3 fasteners. See Below
NOTE: For reliable operation the ground terminal must be connected to the plasma
power supply positive ground. This connection provides the grounded positive arc voltage
sense point.
WARNING!
Connect to WORK
(positive ground)