EasyManua.ls Logo

Hypertherm MicroEdge - Absolute Home Position; Home Offset Distance; Home Switch Normally; Home Direction

Hypertherm MicroEdge
574 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Password Setups 334
Absolute Home Position
Defines the position of the axis when the Home Limit Switch or Marker Pulse is detected.
Home Offset Distance
Allows the user to set an offset distance from the Home Limit Switch.
Home Switch Normally
If a Home Limit Switch is used, the user is prompted for switch polarity.
Home Direction
Determines which direction the axes will travel during phase one of the homing sequence.
Use Marker Pulse
When enabled, the absolute home position will be assigned at the instant the marker pulse is
detected. It is recommended that the Marker Pulse be used for optimal homing repeatability.
Use Software Travel Limits
The control is capable of running with software Overtravel limit switches based on position. when
enabled, this feature allows the user to select the fault logic of fault or Fast Decel when active. Fault
operates as hardware switches with immediate fault. Fast Decel uses the fast Decel value to ramp
down motion.
Maximum Travel Limit
If Software Overtravels are enabled, the user is prompted for the maximum travel of the cutting
machine.
Minimum Travel Limit
If Software Overtravels are enabled, the user is prompted for the minimum travel of the cutting
machine.