Voyager™ III 520
Light Level
The user has the ability to adjust the intensity of the light pulses used on the fiber optic ring. This
feature is used to compensate for diminished signal due to issues such as ring distance. Low is the
default setting for Voyager III
Drive I/O
The user may select to use I/O options directly supported on the Drive Amplifier. Options are None,
Overtravel and Home Switches only or All I/O. Note: The Drive I/O will populate the general purpose
I/O (both analog and digital) in order from the lowest SERCOS drive axis to the highest SERCOS
drive axis. All I/O is the default setting for SMCC / Voyager III interface.
RECO I/O at Address 50
This parameter is set to Yes if the Indramat RECO I/O module is being used to expand the total
number of I/O being used on the standard fiber optic ring. Note: The RECO I/O will populate the
general purpose I/O (both analog and digital) following all drive I/O. The default setting for Voyager III
is NO.
HTA I/O at Address 70
This parameter is set to Yes if one of the SERCOS to Analog cards is set to be used for I/O
expansion.
Common Status Messages
Starting Up Drives on SERCOS Ring. Phase 1 -4
This is a status message to indicate the SERCOS ring power up and will advance through phases 1-
4. Failure to reach phase 4 indicates a problem with power up. Cycle power to initiate SERCOS
phase up again. If the system repeatedly fails to enable the SERCOS ring, contact your vendor for
assistance.
SERCOS Ring not Running. Restart Ring?
This status message indicates the SERCOS ring is currently not running. You may see this when a
command such as a motion command is requested but the RING was not enabled. Restart of the
ring is recommended.
Updating SMCC software.....
After a control software update, the SERCOS to Analog card software may also be updated at restart
of SERCOS ring. It is important not to interrupt this update sequence.
SERCOS Ring Not Running. Please Check Power, Status of LEDs on Drives and I/O Modules,
Fiber Optic Ring Connections and SERCOS Baud Rate.
This status message indicates the SERCOS ring is not running after power up. It is recommended to
check hardware and parameters then restart the ring by power cycle.
New Setups May Require Restarting SERCOS Ring to Take Effect. Restart SERCOS Ring?
When changes are made to system configuration that affect the SERCOS ring operation, you may be
prompted to restart the ring. Restart of the ring is recommended.

Table of Contents

Other manuals for Hypertherm MicroEdge

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm MicroEdge and is the answer not in the manual?

Hypertherm MicroEdge Specifications

General IconGeneral
BrandHypertherm
ModelMicroEdge
CategoryControl Systems
LanguageEnglish

Related product manuals