Edge Ti™ 504
Mating Connector
Use Hypertherm cable CABL-0207 or recommended 9 Pin Dsub (or equivalent)
Connector AMP #205204-3
Backshell Northern Technology #C88000209
Pins AMP #1-66506-0
Cabling: Use Belden # 9540 or equivalent
Plasma Interface
A plasma interface is provided as standard for Edge TI. This feature is used in conjunction with a
Plasma Interface Module to provide connections at the Plasma Supply. Inputs and outputs are dry
contact mode. Arc voltage is assigned to Analog Input 5. Please refer to Sensor™ PHC manual for
additional information.
Plasma Interface Pinout (15 Pin Dsub)
Pin# Description
1 Field +12VDC
2 Field +12VDC
3 Plasma Start Output (Cut Control)
4 Plasma Start Output (Cut Control)
5 Hold Ignition Output
6 Hold Ignition Output
7 Transfer Input (Cut Sense)
8 Transfer Input (Cut Sense)
9 Field Common
10 Field Common
11 Field Common
12 Field Common
13 Field Common
14 Electrode Arc Voltage ()
15 Work Arc Voltage (+)
Mating Connector
Use Hypertherm cable CABL-0208 or recommended 15 Pin Dsub (or equivalent).
Connector AMP #205206-1
Backshell Northern Technology #C88000207
Pins AMP #1-66506-0
Cabling: Use Belden # 9541

Table of Contents

Other manuals for Hypertherm MicroEdge