Voyager™ III 526
It is recommended that the Hold Ignition Input be wired to the Power Supply through an external relay
from the I/O connector. Please refer to instructions from supply manufacturer for details on
connection to the Hold Ignition Input.
Voltage Divider Card Pinout ( Series 3 )
Part # PBS-0061
Divider PCB - 2C Connector J1
Pin # Description
1 85 -265 VAC Power Input ( 47-63Hz )
2 85 -265 VAC Neutral Input
Mating Connector
2C Phoenix Connector Phoenix Part # 1840366
Divider PCB - 8C Connector J2 to Control Analog Connector
Pin # Description
1 +24 VDC Common
3 Nozzle Contact Sense
4 Nozzle Contact Enable
6 Analog Out +
7 Analog Out
8 E Ground
Mating Connector
8C Phoenix Connector Phoenix Part # 1803633
Divider PCB - 5C Connector J3 to Plasma Supply / Table
Pin # Description
1 Ground ( Chassis Ground )
2 Electrode ( Plasma DC )
3 Work ( Plasma DC + )
4 NC
5 Shield ( Nozzle Contact )