Setups 60
Purge Time
Specifies the time delay from torch ignition until motion is enabled.
Pierce Time
Specifies the time delay from when cutting tool completes lowering until motion is initiated at Creep
Speed. Used to allow the cutting tool to completely pierce the material before moving.
Creep Time
Specifies the amount of time after piercing the part that the torch travels at Creep Speed. Creep
Speed is determined by a setup parameter at the Speeds setup screen and is a percentage of the
programmed cut speed. After the Creep Time is completed, the control accelerates to full cut speed.
Abrasive Off Time
The Abrasive Off delay parameter species the amount of time the abrasive will remain on at the end
of a cut.
Abrasive Charging
When selected, the Abrasive Charging feature will charge or fill the abrasive into the cutting system
for use while cutting.