Sensor™ THC 380
Cut Setups
THC Voltage Offset
The THC Voltage Offset Parameter is used to offset the individual Sensor THC™ Arc Voltages from
the master set Arc Voltage. This allows the individual THCs to be adjusted to compensate for
consumable wear and obtain optimum cut quality.
Note: The THC Voltage Offset parameter may be automatically adjusted using the Volts per Minute
parameter of the Change Consumable feature. Please refer to the Change Consumable information
in this guide for additional details.