Sensor™ THC 387
Skip IHS Within
To increase cutting productivity , the Skip IHS Within feature is used to disable Initial Height Sense at
pierce points if it falls within the selected distance. The distance is measured from the end point of
the cut segment to the next pierce point. If this distance falls within the selected Skip IHS Within
distance, no IHS will take place.
Preflow During IHS
Selecting ON will activate Preflow during the IHS cycle.
Nozzle Contact IHS
This parameter would be set to ON to select the Sensor THC to use Contact Sense to detect the
plate during the IHS cycle. It is recommended that Nozzle Contact Initial Height Sense be used when
cutting light gauge material to prevent plate deflection.