Automated Plasma Interface 450
Save Cut Charts
Pressing the Save Cut Charts soft key allows the user to save the current User and Factory
databases to Diskette or USB memory stick. User files are designated with a .usr file extension and
the factory files are designated with a .fac file extension
Examples of user and factory file names.
Mild Steel-HT4400-HD4070.usr
Mild Steel-HT4400-HD4070.fac
Load Cut Charts
Pressing the load Cut Charts soft key allows the user to load the factory default database files which
are supplied by Hypertherm in a Text file (.txt), user files (.usr) or factory files (.fac) from Diskette or
USB memory stick.
Factory text file names.
Mild Steel Cut Chart Data mschart.txt
Aluminum Cut Chart Data alchart.txt
Stainless Steel Cut Chart Data sschart.txt
It is recommended that the Database be updated through the control rather than the Power Supply if
the serial communications link is enabled.
Test Preflow
Pressing the Test Preflow soft key performs the Test Preflow Gases feature at the Plasma supply.
Test Cutflow
Pressing the Test Cutflow soft key performs the Test Cutflow Gases feature at the Plasma supply.
Notes:
- Please refer to the power supply operators manual for complete information on the operation and
setup of the Plasma supply.
- A serial communications port for the Plasma supply must first be selected at the Port
configuration screen to be enable the feature for use.
- The Plasma supply parameters must first be enabled in the password protected Station
Configuration screen to allow the Cut Chart Information for the Plasma supply to be available for
use.
- Power Supplies equipped with the Integrated Command
®
THC may be used with the control
setups. The Command
®
THC must first be enabled for use in the password protected Station
Configuration Screen.

Table of Contents

Other manuals for Hypertherm MicroEdge

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm MicroEdge and is the answer not in the manual?

Hypertherm MicroEdge Specifications

General IconGeneral
BrandHypertherm
ModelMicroEdge
CategoryControl Systems
LanguageEnglish

Related product manuals