Password Setups 324
use. The torch ignition is held off by the Hold Ignition Input to the power
supply from the control.
Raise /Lower 4070 1-2 Exclusive to the HD4070
®
multiple power supply configuration, the Raise
/ Lower 4070 Torch Input is used as a manual raise/lower command to
the selected HD4070
®
integrated THC through the control serial – power
supply communication link.
X +Overtravel Switch This input indicates that the machine has traveled into its full positive
travel in the X axis. If the hardware overtravels are enabled and this input
is activated, the control will stop all motion, generate a fault message
and only allow manual motion in the X axis negative direction.
X –Overtravel Switch This input indicates that the machine has traveled into its full negative
travel in the X axis. If the hardware overtravels are enabled and this input
is activated, the control will stop all motion, generate a fault message
and only allow manual motion in the X axis positive direction.
Y +Overtravel Switch This input indicates that the machine has traveled into its full positive
travel in the Y axis. If the hardware overtravels are enabled and this input
is activated, the control will stop all motion, generate a fault message
and only allow manual motion in the Y axis negative direction.
Y –Overtravel Switch This input indicates that the machine has traveled into its full negative
travel in the Y axis. If the hardware overtravels are enabled and this input
is activated, the control will stop all motion, generate a fault message
and only allow manual motion in the Y axis positive direction.
Power Supply OK This is an input used for the optional Automated Process Controller
(APC). It is used to confirm a ready condition from the Plasma Power
Supply before beginning the cut process.
Fast Stop The Fast Stop input is used as an urgent stop input command to the
control. When the Fast Stop input becomes active, the control will
decelerate motion using a special Fast Stop Decel parameter, and forces
the operator to the Pause Screen. One second after the input becomes
active, the Drive Enable output from the control will turn off and disable
motion. Position information and I/O points will be maintained while the
input is active. This will allow the operator to recover the last position
after the input has been cleared. Note: The Fast Stop Decel parameter
is located on the password protected Speeds setup screen.